Products

VEDAFEU N Blanket Firestop systems

COMPRESSIBILITY

  UP TO - 75 %

 

INSTALLATION

QUICK

AND

EASY

 

ORIENTATION

HORIZONTAL

AND

VERTICAL

  • Movement
  • Firestop
  • Joint Width
  • Tested and approved

  • International certifications delivered by world renowned official and independent

Our VEDAFEU N fire stop joint range, including fire stop joint covers and fire blankets, conforms to several certifications in respect of horizontal and vertical joints. These fire stop joint covers are specially designed to ensure the fire integrity and gas-tightness of expansion joints with large gaps and/or large movements. Tested with movements of +50%, all our VEDAFEU N fire blankets have an EI classification for fire integrity and gas-tightness, in compliance with current European and French standards, including EN 13501-2 and EN 1366-4 norms. VEDAFEU N fire stop joint covers are available in several sizes to suit joint gaps from 100 mm to 840 mm.

VEDAFEU N fire stop joint covers can be used for horizontal and vertical joints requiring fire stop joint protection, e.g. floor, wall and ceiling joints, joints between prefabricated façade elements, and seismic joints. They are also suitable for fire partitions, conduit penetrations, services ducts, protection of neoprene supports, and for joints on plate edges. VEDAFEU N fire stop joint covers must be installed in accordance with the approved instructions for the relevant classification certifications. VEDAFEU N systems provide effective protection for buildings that house works of art, as well as for hospitals, offices, industrial and residential buildings, hotels, shopping centres, car parks, schools, colleges, stations, airports, stadiums, and more.

The composition of VEDAFEU N fire stop blankets and their method of installation are patented. Handling is easy and safe: VEDAFEU N fire stop blankets do not contain any asbestos (which is a banned substance) or refractory ceramic fibres which are dangerous to health. This is because they are manufactured with long mineral fibres that exceed 6 microns in diameter and which cannot enter the respiratory tract, and are thus classified as not dangerous to health by the International Agency for Research on Cancer (IARC).


Our standard range is suitable for joints with initial gaps from 100 mm to 560 mm. Other widths are available on request.

Reference
VEDAFEU N Blanket
Gap (mm)
W
Movements (mm)
Visible width (mm)
S
Total width (mm)
B
Height (mm)
H
Loads
Vedafeu N150 75 --> 225 /- 50% 150 - - -
Vedafeu N200 100 --> 300 /- 50% 200 - - -
Vedafeu N300 150 --> 450 /- 50% 300 -
Vedafeu N400 200 --> 600 /- 50% 400 - - -
Vedafeu N560 280 --> 840 /- 50% 560 - - -
Reference
VEDAFEU N Blanket
Vedafeu N150
Gap (mm)
W
75 --> 225
Movements (mm)
/- 50%
Visible width (mm)
S
150
Total width (mm)
B
-
Height (mm)
H
-
Loads
-
Reference
VEDAFEU N Blanket
Vedafeu N200
Gap (mm)
W
100 --> 300
Movements (mm)
/- 50%
Visible width (mm)
S
200
Total width (mm)
B
-
Height (mm)
H
-
Loads
-
Reference
VEDAFEU N Blanket
Vedafeu N300
Gap (mm)
W
150 --> 450
Movements (mm)
/- 50%
Visible width (mm)
S
300
Total width (mm)
B
Height (mm)
H
Loads
-
Reference
VEDAFEU N Blanket
Vedafeu N400
Gap (mm)
W
200 --> 600
Movements (mm)
/- 50%
Visible width (mm)
S
400
Total width (mm)
B
-
Height (mm)
H
-
Loads
-
Reference
VEDAFEU N Blanket
Vedafeu N560
Gap (mm)
W
280 --> 840
Movements (mm)
/- 50%
Visible width (mm)
S
560
Total width (mm)
B
-
Height (mm)
H
-
Loads
-

The load-bearing capacity is always indicated for a joint in its initial position. In case of opening movements, the load-bearing capacity significantly reduces and the product will thus be only adapted for a light pedestrian traffic. The indicated load-bearing capacities are based on pneumatic wheels vehicles with a contact surface of 200x200 mm.